GVC1 Firmware v26.1.3
An update to Valve Controller firmware was released to the public on Wednesday, January 11th, 2023. Rollout of new firmware occurs incrementally to all devices over a 3-day period.
Added
- New command (PAIR_RESET = 51) to remove ALL paired devices
- Max timeout while waiting for IP assignment during OTA set to 30s
- RF modem now upgradable via OTA
- Faster upgrade process for early-production devices stuck on legacy firmware
- Enabled API via RS-485 on remote probe port
- Download PDF: GVC1 v26.1.3 API Reference
Updated
- Increased motor controller current monitoring sample size for better accuracy
- Nominal Leak Detector battery voltage updated to handle change from ER 3.6V to CR 3.0V batteries